| Posted on 5/13/08 at 04:12 AM | |
|
|
Hello Laura, Your dryer measures the temperature at the face of the heater. So 660 deg f. on the control unit could be about 300 at the belt depending on the height you set the heater to. Water based ink usually requires 2-3 times longer then plastisol to cure which makes the EononRed I a small dryer for the job. Do you get the Scrub-Air option or power exhaust on your dryer? Forced hot air helps evacuate the moisture from the ink as well as a strong exhaust. Give a call to the factory and ask for Mark Clewell or myself, and we will try to help you out. Regards, Mark Vasilantone, Vastex International Inc. 800-482-7839. | |
|