| Posted on 8/7/07 at 05:25 AM | |
| As Richard pointed out, your screens can really only be globally crosslinked with either light (near UV) or excessive heat (over 105° F). Be sure the screens are kept under the appropriate safe lights (or filtering sleeves) until after water development. If you put the screens in a dryer after coating, could the dryer temperature have been too high? | ||
|